TKD modular precision power distribution cabinet with 7-inch touch screen monitoring, 160–400A input and up to 144-way output for data centers

TKD Modular Precision Power Distribution Cabinet for Data Centers

TKD Series
Rated Voltage
208 / 380 / 400 / 415 VAC
Input Current
IT 160 / 250 / 400 A; AC 160 / 250 A
Type
Modular precision distribution, double/single bus
Output
up to 144-way 1P or 48-way 3P micro-break
Monitoring
7-inch touch screen, full circuit metering
Dimensions
600×1200×2000 mm, <380 kg

Lead Time: 7 – 15 days | Shipping: Worldwide (sea / air / express) | Warranty: 2.5 years full machine

ISO 9001IEC 61439CE

Excerpt

The TKD Series Modular Precision Power Distribution Cabinet is a data center-grade low-voltage distribution unit that bridges UPS output to individual server racks. Rated at 208–415 VAC with input current from 160 to 400 A for IT loads and up to 250 A for air conditioning circuits, it supports up to 144 single-phase or 48 three-phase output circuits with configurable breaker sizes from 10 A to 63 A. The modular design allows flexible expansion on site — add output breakers as your rack count grows. Choose between double-bus (redundant) or single-bus architecture based on your availability requirements. A 7-inch touch screen provides real-time monitoring of main circuit parameters (voltage, current, power, power factor, energy, harmonics) and sub-circuit status (current, load rate, breaker state) — all visible from one screen. The cabinet is 600×1200×2000 mm, floor-mounted, and pairs directly with the TKM-A modular data center and TKM-R series as the standard power distribution layer. For UPS powering these systems, see the ATP C 10–200 kVA or ARP modular UPS.

Key Features

✓

Up to 144 Output Circuits

Distributes power to up to 144 single-phase or 48 three-phase rack circuits from one cabinet.

✓

Double-Bus Redundancy Option

Choose double-bus architecture for high-availability facilities, or single-bus for cost-sensitive deployments.

✓

7-inch Touch Screen Monitoring

Real-time display of voltage, current, power, energy, harmonics and breaker status across all circuits.

✓

Modular Expansion

Add output breakers (10A–63A) as your rack count grows — no need to replace the whole cabinet.

✓

160–400A IT + 160–250A AC Input

Separately feeds IT loads and air conditioning circuits from one unit.

✓

Factory Tested, Plug-and-Play

Standardized production, pre-debugged and tested, simple floor installation on site.

Technical Specifications

Basic Parameters
Rated Voltage208 / 380 / 400 / 415 VAC
Rated Input CurrentIT: 160 / 250 / 400 A; Air conditioner: 160 / 250 A (optional)
Bus ArchitectureDouble bus (standard) or single bus (optional)
Output SwitchUp to 144-way 1P micro-break or 48-way 3P micro-break (optional, combinable)
Output Breaker Rating10A / 16A / 20A / 32A / 40A / 63A (optional)
Monitoring
Display7-inch touch screen
Main Circuit MonitoringVoltage, current, active/reactive/apparent power, power factor, energy, harmonics
Sub-Circuit MonitoringCurrent, load rate, active power, energy, breaker status
Physical
Dimensions (W×D×H)600×1200×2000 mm
InstallationFloor installation or base installation
Weight< 380 kg

Typical Applications

The TKD Series is engineered for environments where a single power event can stop production or lose revenue. Wherever continuity matters — in data centres, plants, grids and critical sites — it delivers clean, reliable power when you need it most.

Data Centre & Server Room

Data Centre & Server Room

Keeps racks, cooling and network infrastructure online through mains failure, brownouts and switching, with zero transfer time and clean sinewave output.

Telecommunications

Telecommunications

Protects switching, transmission and BTS/edge sites where a dropped call or a down base station means lost revenue.

Healthcare

Healthcare

Provides clean, uninterrupted power for medical imaging, diagnostics and life-support equipment.

Semiconductor & High-Tech

Semiconductor & High-Tech

Guards precision tools and clean-room utilities where a single glitch can scrap an entire batch.

Commercial & Office Buildings

Commercial & Office Buildings

Delivers quiet, reliable backup for lifts, security, HVAC and business-critical office loads.

Education

Education

Keeps campus networks, server rooms, e-learning platforms and administrative systems running through lectures, exams and online classes.

Government

Government

Secures government data centers, public service systems, emergency communications and citizen-facing services where uptime is a public trust.

Finance

Finance

Protects trading floors, core banking systems, ATM networks and financial data centers where an outage means direct revenue loss and regulatory penalties.

Frequently Asked Questions

What is a precision power distribution cabinet?

It is a data center-grade electrical cabinet that distributes UPS output power to individual server racks. The TKD cabinet provides circuit-level protection, metering and monitoring — replacing manual wiring in traditional electrical rooms.

What is the difference between single bus and double bus?

Single bus distributes power from one source. Double bus provides two independent buses — if one bus has a fault, the other continues powering critical loads. Double bus is recommended for high-availability IDC and data center deployments.

How many output circuits can I get?

Up to 144 single-phase circuits or 48 three-phase circuits. Breaker sizes from 10A to 63A are configurable. Additional circuits can be added later as your data center expands.

Does it integrate with modular data centers?

Yes. The TKD is designed as the standard power distribution layer for the TKM-A and TKM-R modular data center series. It pairs with UPS systems like the ATP C 10–200 kVA or ARP modular UPS.

What can the 7-inch touch screen monitor?

Main circuit voltage, current, power, power factor, energy and harmonics; plus sub-circuit current, load rate and breaker status. This helps identify overloaded circuits before they trip.

Who should I contact for this UPS — the factory or Brigoind?

Please contact Brigoind. We are the authorized distributor & engineering partner for AVIC-TECH power systems outside China.
What you receive is far more than a UPS unit — it is a full project delivery package, including load calculation, system sizing, single-line diagram design, battery runtime calculation, tender document preparation, lead-time confirmation, export packaging, ocean freight arrangement and customs documentation.
The UPS equipment is manufactured at AVIC-TECH’s factory in China. Every unit comes with factory test reports and relevant product certification documents, and is covered under AVIC-TECH’s official warranty.
Brigoind handles your project communications from initial inquiry through on-site commissioning guidance with multi-language support.
We coordinate after-sales support aligned with your local time zone.
For urgent inquiries, reach us via WhatsApp: +86 135 9996 3955.

Related Products

Why Brigoid

15+
Years Manufacturing
60+
Export Countries
2,000+
Projects Delivered
24/7
Technical Support