Lead Time: 7 – 15 days | Shipping: Worldwide (sea / air / express) | Warranty: 2.5 years full machine
IEC 62619CEUN38.3
Excerpt
The AES-D series is a LiFePO4 lithium iron phosphate energy storage system purpose-built for DC panel applications in power generation plants, precise power distribution systems, and electrical substations. Covering DC110V and DC220V system voltages with capacities from 100Ah up to 2000Ah, it delivers scalable energy storage from 2.72 kWh per module up to 43.52 kWh per full DC220V cabinet.Built on a highly stable LFP cell chemistry rated for 5000 cycles at 50% depth of discharge, the AES-D system features an intelligent BMS management platform with centralized monitoring and communication via CAN, RS485, and dry-contact interfaces. It supports multi-site integration and remote upgrade, making it suitable for distributed substation and power plant deployments.Significantly reducing footprint and weight compared to traditional VRLA battery banks, the AES-D cabinet is available in two standard sizes (800×800×2260 mm or 800×600×2260 mm) with RAL7035 industrial finish. Operating range 0°C to 40°C, self-discharge below 3% per 30 days. It is designed as a direct replacement for flooded lead-acid and VRLA battery sets in substation DC systems, switchgear tripping supplies, and control power applications.
Key Features
✓
43.52 kWh Max per Cabinet
DC220V configuration with 9 parallel modules delivers up to 43.52 kWh, replacing entire VRLA battery rooms in a single cabinet.
✓
5000-Cycle LFP Chemistry
LiFePO4 cells rated for 5000 cycles at 50% DoD, cutting substation battery replacement cycles by 3–4x vs lead-acid.
✓
DC110V / DC220V Dual Voltage
Covers both 110V and 220V DC control systems with modular stacking, matching standard substation DC bus voltages.
✓
70% Smaller Footprint
Modular 440×440×175 mm cells in a compact 800×600/800×2260 mm cabinet, reducing battery room floor space significantly.
✓
Intelligent BMS + Multi-site Monitoring
Built-in BMS with CAN/RS485/dry-contact enables centralized monitoring and remote upgrade across multiple substation sites.
✓
1C Continuous Charge / Discharge
1C rate supports both fast recharge and reliable backup supply for switchgear tripping and control circuits.
Technical Specifications
Module Electrical Parameters
Rated Capacity
25 Ah / 50 Ah / 100 Ah / 200 Ah
Cell Type
Lithium Iron Phosphate (LiFePO4 / LFP)
Module Rated Voltage
108.8 V / 54.4 V / 25.6 V / 19.2 V
Discharge Rate
1C (continuous)
Charge Rate
1C (continuous)
Max Module Capacity
2.72 kWh / 3.84 kWh / 5.12 kWh / 5.44 kWh
Module Output Power
2.72 kW / 3.84 kW / 5.12 kW / 5.44 kW
Module Dimensions (W×D×H)
440 × 440 × 175 mm / 440 × 440 × 131 mm
Module Weight
29 kg / 36 kg / 44 kg / 46 kg (±2 kg)
System Cabinet Configuration
DC110V System — Energy Range
2.72 kWh / 5.44 kWh / 10.88 kWh / 21.76 kWh
DC220V System — Energy Range
5.44 kWh / 10.88 kWh / 21.76 kWh / 43.52 kWh
Cycle Life
5000 cycles @ 50% Discharge Depth
Communication Interface
CAN / RS485 / Dry Contact
Protective Functions
Overcharge, Over-discharge, Over-temperature, Overcurrent, Short Circuit
Mechanical & Environmental
Operating Temperature
0°C ~ 40°C (recommended 20–25°C)
Self-discharge Rate
< 3% per 30 days (at 0–30°C ambient)
Cabinet Dimensions (W×D×H)
800 × 800 × 2260 mm or 800 × 600 × 2260 mm
Cabinet Weight
Module weight × N + 250 kg cabinet
Color
RAL7035
Note: Parameters based on 25°C ambient. Specifications subject to change without notice.
Typical Applications
The AES-D-25 / AES-D-50 / AES-D-100 / AES-D-200 (Ah options) is engineered for environments where a single power event can stop production or lose revenue. Wherever continuity matters — in data centres, plants, grids and critical sites — it delivers clean, reliable power when you need it most.
Utility Power & Grid
Protects protection, control, SCADA and metering systems in utility generation, transmission and distribution networks.
Industrial Plants
Guards PLCs, drives, robots and process lines against grid dips and outages, cutting downtime, scrap and rework.
Oil & Gas
Protects DCS, PLC, SCADA, ESD and instrumentation onshore and offshore, where process continuity and personnel safety are non-negotiable.
Power Plant & Substation
Backs up protection, control, SCADA and metering systems in generation, transmission and distribution, even in harsh electrical environments.
Petrochemical & Refinery
Shields batch and continuous process control against voltage events that can destabilise reactors and compressors.
Water & Wastewater Treatment
Keeps pumps, blowers, SCADA and chlorination control running so discharge and supply obligations are never missed.
Steel & Metallurgy
Stabilises drives and melt-shop control against the deep sags and harmonics typical of heavy industrial grids.
Emergency & Black Start
Instantly backs critical loads during outages and islands, and supports generator black-start sequences.
Frequently Asked Questions
Q1: What is the difference between AES-D and traditional VRLA battery sets for DC panels?
The AES-D uses LiFePO4 chemistry with 5000 cycles at 50% DoD (vs 1200–1500 cycles for VRLA), delivers 1C charge/discharge rate, and occupies roughly 70% less floor space. It also eliminates equalization maintenance and acid leakage risks associated with lead-acid batteries in substation environments.
Q2: What DC system voltages does the AES-D support?
The AES-D supports both DC110V and DC220V standard substation DC system voltages. It can be configured with different numbers of series-parallel modules — from 2.72 kWh up to 21.76 kWh for DC110V systems, and up to 43.52 kWh for DC220V systems.
Q3: Can the AES-D be monitored remotely from a central control room?
Yes. The built-in intelligent BMS supports CAN, RS485, and dry-contact communication protocols, enabling centralized monitoring, multi-site integration, and remote firmware upgrades — ideal for distributed substation and power plant SCADA environments.
Q4: What applications is the AES-D battery designed for?
It is specifically engineered for power generation plants, precise power distribution systems, electrical substations, and other power-related DC panel applications — providing reliable DC backup for switchgear tripping circuits, protection relays, and control systems.
Q5: How long does the AES-D battery last in a substation environment?
Rated for 5000 cycles at 50% depth of discharge with 0–40°C operating range, the AES-D typically provides 10–15 years of service life in substation DC supply applications, compared to 5–8 years for conventional VRLA battery banks.
Q6: What is the lead time and shipping for the AES-D series?
Standard configurations ship within 7–15 days with worldwide delivery. Custom cabinet configurations for multi-site substation projects may require 20–30 days. The system arrives pre-assembled and pre-tested for quick on-site commissioning.
Q7: Who should I contact for this UPS — the factory or Brigoind?
Please contact Brigoind. We are the authorized distributor & engineering partner for AVIC-TECH power systems outside China.
What you receive is far more than a UPS unit — it is a full project delivery package, including load calculation, system sizing, single-line diagram design, battery runtime calculation, tender document preparation, lead-time confirmation, export packaging, ocean freight arrangement and customs documentation.
The UPS equipment is manufactured at AVIC-TECH’s factory in China. Every unit comes with factory test reports and relevant product certification documents, and is covered under AVIC-TECH’s official warranty.
Brigoind handles your project communications from initial inquiry through on-site commissioning guidance with multi-language support.
We coordinate after-sales support aligned with your local time zone.
For urgent inquiries, reach us via WhatsApp: +86 135 9996 3955.