| Electrical Parameters | |
| Nominal Voltage | 12 V DC |
| Capacity Range (TB-AGM) | 7 – 250 Ah (20-hour rate) |
| Capacity Range (TBJ-Gel) | 65 – 200 Ah (20-hour rate) |
| Battery Type | VRLA, sealed, valve-regulated, AGM or Gel |
| Plate Alloy | Lead-calcium, high-purity |
| Separator | AGM (absorbent glass mat) |
| Operating Conditions | |
| Operating Temperature | -15°C ~ +40°C |
| Float Charge Voltage | 13.6 – 13.8 VDC (25°C) |
| Cycle Charge Voltage | 14.4 – 14.9 VDC (25°C) |
| Self-Discharge | < 3% per month (25°C) |
| Design Life | 5–10 years (float, 25°C) |
| Physical | |
| Container Material | ABS, flame-retardant |
| Terminals | F2 / M6 / M8 (by model) |
| Dimensions Range | 151×65×95 mm (7Ah) to 522×268×226 mm (250Ah) |
| Weight Range | 2.06 kg (7Ah) to 69 kg (250Ah) |

TB/TBJ Series 12V VRLA Battery — AGM & Gel Sealed Lead-Acid for UPS and Telecom
Lead Time: 7 – 15 days | Shipping: Worldwide (sea / air / express) | Warranty: 2.5 years full machine
Excerpt
The TB/TBJ Series is a 12V valve-regulated lead-acid (VRLA) battery family covering 7 to 250 Ah, available in both AGM (TB series) and gel (TBJ series) configurations. Built with high-purity lead-calcium alloy plates and AGM separators, these sealed maintenance-free batteries are designed for UPS backup, telecom power systems, security systems, emergency lighting and solar off-grid applications.The AGM (absorbent glass mat) TB series offers excellent high-rate discharge performance, making it ideal for UPS systems where short, high-current bursts are needed. The gel TBJ series provides deeper cycle capability and longer float life, suitable for cyclic applications and wider temperature environments. Both use an ABS flame-retardant container with no leakage and low self-discharge rate, and can be installed in any orientation — upright, on a side, or stacked.Operating from -15°C to +40°C, the batteries are compatible with all major UPS brands including the ATP series, ATP C 10–200 kVA, and ARP modular UPS in our Network Energy Solutions lineup. For longer-life and higher-temperature applications, LiFePO4 lithium battery packs are also available as an upgrade.
Key Features
7–250 Ah Full Capacity Range
Covers from 7Ah small security systems to 250Ah UPS backup banks — match the exact capacity your UPS runtime requires without over-sizing.
AGM & Gel Two Options
AGM (TB) delivers high-rate discharge for UPS; Gel (TBJ) provides deep-cycle durability for cyclic and solar applications — choose based on your duty cycle.
Sealed Maintenance-Free Design
No water topping-up, no acid leakage, no fumes — install in offices, telecom cabinets and indoor spaces without ventilation concerns.
Low Self-Discharge Rate
High-purity lead-calcium alloy plates reduce self-discharge to less than 3% per month at 25°C — store for up to 6 months before recharge.
Wide Temperature Range: -15°C to +40°C
Operates reliably in unheated telecom shelters, basement equipment rooms and coastal installations where standard batteries may fail prematurely.
Multi-Directional Installation
ABS container allows mounting upright, on side or stacked — ideal for telecom cabinets and UPS battery racks where space is constrained.
Technical Specifications
Typical Applications
The TB / TBJ Series is engineered for environments where a single power event can stop production or lose revenue. Wherever continuity matters — in data centres, plants, grids and critical sites — it delivers clean, reliable power when you need it most.
Data Centre & Server Room
Keeps racks, cooling and network infrastructure online through mains failure, brownouts and switching, with zero transfer time and clean sinewave output.
Telecommunications
Protects switching, transmission and BTS/edge sites where a dropped call or a down base station means lost revenue.
Industrial Plants
Guards PLCs, drives, robots and process lines against grid dips and outages, cutting downtime, scrap and rework.
Healthcare
Provides clean, uninterrupted power for medical imaging, diagnostics and life-support equipment.
Commercial & Office Buildings
Delivers quiet, reliable backup for lifts, security, HVAC and business-critical office loads.
Emergency & Black Start
Instantly backs critical loads during outages and islands, and supports generator black-start sequences.
Remote & Microgrid Sites
Delivers reliable power off-grid or on weak grids, cutting diesel runtime, fuel cost and maintenance.
Edge & Telecom Sites
Compact, high-temperature-tolerant lithium backup that frees floor space and withstands extreme site conditions.
Frequently Asked Questions
What is the difference between AGM and gel VRLA batteries?
AGM batteries (TB series) use glass-fiber separators to absorb electrolyte, delivering excellent high-rate discharge performance — ideal for UPS systems. Gel batteries (TBJ series) use silica gel electrolyte, offering deeper cycle life and better temperature tolerance — suitable for solar and cyclic applications. Both are 12V sealed VRLA designs.
Are these batteries compatible with my UPS?
Yes. TB/TBJ 12V batteries are standard-sized VRLA cells compatible with all major UPS brands. They pair directly with our ATP Frame 1–10 kVA, ATP C 10–200 kVA, and ARP modular UPS series. Send your UPS model for compatibility confirmation.
How long will the battery backup last?
Runtime depends on UPS size, battery count and load. A typical 10 kVA UPS with 20×12V/100Ah batteries provides 10–15 minutes at full load. For longer backup, add more battery strings or consider BESS energy storage systems.
Should I choose AGM or gel for my application?
Choose AGM (TB) for UPS standby power, security systems and emergency lighting where high-rate discharge is needed. Choose Gel (TBJ) for solar off-grid, cyclic operation and high-temperature environments. For longest life and fastest charge, LiFePO4 lithium batteries offer 4× longer cycle life.
Can these batteries be mounted on their side?
Yes. The sealed VRLA design allows installation in any orientation — upright, on a side, or stacked — without leakage. This makes them ideal for telecom cabinets and rack-mounted UPS where space is constrained.
Who should I contact for this UPS — the factory or Brigoind?
Please contact Brigoind. We are the authorized distributor & engineering partner for AVIC-TECH power systems outside China.
What you receive is far more than a UPS unit — it is a full project delivery package, including load calculation, system sizing, single-line diagram design, battery runtime calculation, tender document preparation, lead-time confirmation, export packaging, ocean freight arrangement and customs documentation.
The UPS equipment is manufactured at AVIC-TECH’s factory in China. Every unit comes with factory test reports and relevant product certification documents, and is covered under AVIC-TECH’s official warranty.
Brigoind handles your project communications from initial inquiry through on-site commissioning guidance with multi-language support.
We coordinate after-sales support aligned with your local time zone.
For urgent inquiries, reach us via WhatsApp: +86 135 9996 3955.