TKC-N inter-column precision air conditioner 25–66 kW installed between server racks for high-density data center cooling

TKC-N Inter-Column Precision Air Conditioner, 25–66 kW

TKC-N025, TKC-N030, TKC-N040, TKC-N050, TKC-N065
Cooling Capacity
25.1 – 65.7 kW
Power Supply
380V, 50Hz, 3-phase
Type
Inter-column air-cooled precision AC, redundant fans
Air Volume
5500 – 12000 m³/h
Heating
6 kW
Humidification
1.5 – 3 kg/h

Lead Time: 7 – 15 days | Shipping: Worldwide (sea / air / express) | Warranty: 2.5 years full machine

ISO 9001CE

Excerpt

The TKC-N Series is an inter-column air-cooled precision air conditioner covering 25.1 to 65.7 kW, designed for large IDC data centers and micro-module deployments. Installed between server racks in a cold aisle arrangement, it delivers close-coupled cooling that isolates hot and cold airflow for highly efficient heat removal. Redundant fan design ensures safety and reliability — if one fan fails, the other continues cooling. The precision cooling near the cabinet supports higher rack power density without requiring raised floor ductwork. Productized modular design means low requirements for data center layout, on-site engineering and installation. It pairs with the TKM-A double-row modular data center as the standard column cooling solution.

Key Features

✓

25–66 kW Inter-Column Cooling

Installs between server racks for close-coupled heat removal

✓

Redundant Fan Design

If one fan fails, backup continues cooling — no downtime

✓

Cold/Hot Aisle Isolation

Maximizes cooling efficiency, supports high-density racks

✓

Productized Modular Design

Factory prefabricated, fast on-site deployment

✓

Heating + Humidification

6 kW heating, 1.5–3 kg/h humidification

✓

Sensible Heat Ratio = 1

All cooling goes to removing IT heat, no wasted dehumidification

Technical Specifications

Performance
ModelTKC-N025 / N030 / N040 / N050 / N065
Total Cooling Capacity25.1 / 31.1 / 40.9 / 51.2 / 65.7 kW
Sensible Heat Ratio1.0
Air Volume5500 / 5800 / 8500 / 10000 / 12000 m³/h
Electrical
Heating Capacity6 kW
Humidification Capacity1.5 / 3 kg/h
Full Load Current27.9 / 34.6 / 37.7 / 45.4 / 56.5 A
Physical
Dimensions (W×D×H)300×1200×2000 mm (25–31 kW) / 600×1200×2000 mm (41–66 kW)
Weight260 / 320 / 360 / 420 / 460 kg

Typical Applications

The TKC-N025, TKC-N030, TKC-N040, TKC-N050, TKC-N065 is engineered for environments where a single power event can stop production or lose revenue. Wherever continuity matters — in data centres, plants, grids and critical sites — it delivers clean, reliable power when you need it most.

Data Centre & Server Room

Data Centre & Server Room

Keeps racks, cooling and network infrastructure online through mains failure, brownouts and switching, with zero transfer time and clean sinewave output.

Telecommunications

Telecommunications

Protects switching, transmission and BTS/edge sites where a dropped call or a down base station means lost revenue.

Healthcare

Healthcare

Provides clean, uninterrupted power for medical imaging, diagnostics and life-support equipment.

Semiconductor & High-Tech

Semiconductor & High-Tech

Guards precision tools and clean-room utilities where a single glitch can scrap an entire batch.

Commercial & Office Buildings

Commercial & Office Buildings

Delivers quiet, reliable backup for lifts, security, HVAC and business-critical office loads.

Education

Education

Keeps campus networks, server rooms, e-learning platforms and administrative systems running through lectures, exams and online classes.

Government

Government

Secures government data centers, public service systems, emergency communications and citizen-facing services where uptime is a public trust.

Finance

Finance

Protects trading floors, core banking systems, ATM networks and financial data centers where an outage means direct revenue loss and regulatory penalties.

Frequently Asked Questions

What is an inter-column (in-row) precision air conditioner?

It is a cooling unit installed between server racks in a data center, providing close-coupled cooling to high-density IT equipment. The TKC-N 25–66 kW eliminates the need for raised floor ductwork and delivers precise cooling near the heat source.

What is the difference between TKC-R and TKC-N?

The TKC-R is rack/top-mounted for small rooms (3.5–12.5 kW). The TKC-N is inter-column for large IDCs (25–66 kW). Cho

Does the redundant fan really matter?

Yes. If one fan fails, the redundant fan continues cooling — no data center downtime. This is critical for 24/7 mission-critical facilities.

What data center size does this cover?

25–66 kW per unit, suitable for medium to large IDC deployments. Pair with the TKM-A double-row modular data center for a complete solution.

Can multiple units work together?

Yes. Multiple TKC-N units can be deployed in parallel in a cold aisle, with N+1 redundancy. For UPS powering these systems, see the ATP C 10–200 kVA or ARP modular UPS.

Who should I contact for this UPS — the factory or Brigoind?

Please contact Brigoind. We are the authorized distributor & engineering partner for AVIC-TECH power systems outside China.
What you receive is far more than a UPS unit — it is a full project delivery package, including load calculation, system sizing, single-line diagram design, battery runtime calculation, tender document preparation, lead-time confirmation, export packaging, ocean freight arrangement and customs documentation.
The UPS equipment is manufactured at AVIC-TECH’s factory in China. Every unit comes with factory test reports and relevant product certification documents, and is covered under AVIC-TECH’s official warranty.
Brigoind handles your project communications from initial inquiry through on-site commissioning guidance with multi-language support.
We coordinate after-sales support aligned with your local time zone.
For urgent inquiries, reach us via WhatsApp: +86 135 9996 3955.

Related Products

Why Brigoid

15+
Years Manufacturing
60+
Export Countries
2,000+
Projects Delivered
24/7
Technical Support