| System Parameters | |
| Rated Output Power | 10 kVA (thermal power variant) |
| Rated AC Voltage | 3P3W / 3P4W, 380 / 400 / 415 VAC |
| Grid Frequency | 50 / 60 Hz |
| Line Entry | Bottom in |
| AC Output | |
| Compensation Ability | 5 – 10 seconds (extended ride-through) |
| Full Response Time | ≤ 1 ms |
| Display & Communication | |
| Display | 10-inch full-color touch screen, Chinese / English bilingual |
| Communication Interface | RS485 / Modbus RTU, dry contact |
| Data Record & Protection | |
| Overall Efficiency | > 99% |
| Energy Storage | Built-in supercapacitor |
| Protection Class | IP45 (dust & humidity resistant) |
| Dimensions (W×D×H) | 600 × 800 × 1950 mm |

AVR Thermal Power Dynamic Voltage Restorer (DVR) — IP45, 10 kVA for Power Plant Auxiliary Systems
Lead Time: 7 – 15 days | Shipping: Worldwide (sea / air / express) | Warranty: 2.5 years full machine
Excerpt
The AVR Thermal Power Dynamic Voltage Restorer (DVR) is a purpose-built power quality unit designed for the harsh environment of thermal power plants. Rated 10 kVA with IP45 protection, it protects critical auxiliary systems — boiler feed pumps, induced-draft fans, forced-draft fans, coal mill drives and compressor controls — from voltage sags, swells and short-duration grid disturbances that can trigger automatic turbine trips and costly shutdowns.Compared to the standard industrial AVR, the thermal-power variant provides extended ride-through of 5–10 seconds (vs. 1–6 seconds standard), because power plant auxiliary processes often require several seconds of stable power to ride through grid disturbances and prevent automatic load rejection. The IP45 enclosure handles dust, humidity and wide temperature swings typical of boiler houses and turbine halls.With a ≤1ms response time and >99% efficiency, the DVR sits in series with the auxiliary power supply and activates only during disturbances — no load transfer, no ongoing loss. RS485/Modbus communication allows integration with plant DCS and SCADA systems for monitoring and event recording.
Key Features
IP45 Harsh Environment Protection
Shields boiler feed pumps and fan drives from dust, humidity and temperature swings in boiler house and turbine hall environments — standard IP30 units fail quickly in these conditions.
5–10s Extended Ride-through
Provides longer compensation duration than standard DVR units, matching the time power plant auxiliary processes need to ride through grid disturbances without triggering automatic turbine trip.
≤1ms Sag Response for Auxiliary Drives
Protects VFD-driven fans and pumps from voltage dips before the drives' undervoltage protection trips — preventing forced outage and boiler shutdown.
Purpose-built for Thermal Power Auxiliaries
Engineered specifically for boiler feed pumps, ID/FD fans, coal mills and compressor controls — not a general industrial unit repurposed for power plant use.
>99% Efficiency, Low Auxiliary Power Loss
Operates at near-zero loss under normal grid conditions because the inverter idles and only activates during disturbances — no ongoing auxiliary load penalty.
DCS & SCADA Integration Ready
RS485/Modbus RTU and dry-contact I/O allow direct connection to plant DCS systems for event recording, disturbance analysis and remote monitoring.
Technical Specifications
Typical Applications
The AVR-T Series (Thermal Power) is engineered for environments where a single power event can stop production or lose revenue. Wherever continuity matters — in data centres, plants, grids and critical sites — it delivers clean, reliable power when you need it most.
Utility Power & Grid
Protects protection, control, SCADA and metering systems in utility generation, transmission and distribution networks.
Industrial Plants
Guards PLCs, drives, robots and process lines against grid dips and outages, cutting downtime, scrap and rework.
Oil & Gas
Protects DCS, PLC, SCADA, ESD and instrumentation onshore and offshore, where process continuity and personnel safety are non-negotiable.
Power Plant & Substation
Backs up protection, control, SCADA and metering systems in generation, transmission and distribution, even in harsh electrical environments.
Petrochemical & Refinery
Shields batch and continuous process control against voltage events that can destabilise reactors and compressors.
Water & Wastewater Treatment
Keeps pumps, blowers, SCADA and chlorination control running so discharge and supply obligations are never missed.
Steel & Metallurgy
Stabilises drives and melt-shop control against the deep sags and harmonics typical of heavy industrial grids.
Mining
Protects hoists, conveyors, ventilation and control systems in remote and weak-grid mine sites.
Frequently Asked Questions
Why do thermal power plants need a dedicated DVR instead of a standard industrial unit?
Power plant auxiliary systems (boiler feed pumps, ID/FD fans, coal mills) have longer process ride-through requirements — typically 5–10 seconds versus 1–6 seconds for standard industrial loads. A shorter dip that doesn’t stop a factory line can still trigger an automatic turbine trip in a power plant. The IP45 enclosure is also required for boiler house and turbine hall environments where dust and humidity would damage a standard IP30 unit.
How does a DVR prevent turbine trip from voltage sag?
When the grid sags, the DVR injects compensation voltage in series within ≤1ms, keeping the auxiliary drives (pumps, fans) running at rated voltage. Without this protection, VFD-driven auxiliaries detect undervoltage and trip, which triggers the turbine protection system — causing a forced outage that can cost tens of thousands of dollars per hour.
What auxiliary loads does the 10kVA DVR protect?
It protects critical control and drive systems: boiler feed pump VFDs, induced-draft and forced-draft fan drives, coal mill control systems, lube oil pump motors, and turbine auxiliary control circuits. Larger motors are typically handled by higher kVA DVR units in the AVR range.
Can the DVR integrate with our plant DCS system?
Yes. RS485/Modbus RTU communication and dry-contact I/O allow direct connection to plant DCS and SCADA systems. The DVR logs every disturbance event (magnitude, duration, timestamp) for compliance reporting and root-cause analysis.
What is the lead time for a thermal power DVR project?
Standard 10kVA IP45 units are typically available within 4–6 weeks. Larger projects requiring site engineering, custom voltage settings or integration with existing DCS systems typically require 8–12 weeks. Contact us with your single-line diagram and disturbance history for a tailored proposal.
Who should I contact for this UPS — the factory or Brigoind?
Please contact Brigoind. We are the authorized distributor & engineering partner for AVIC-TECH power systems outside China.
What you receive is far more than a UPS unit — it is a full project delivery package, including load calculation, system sizing, single-line diagram design, battery runtime calculation, tender document preparation, lead-time confirmation, export packaging, ocean freight arrangement and customs documentation.
The UPS equipment is manufactured at AVIC-TECH’s factory in China. Every unit comes with factory test reports and relevant product certification documents, and is covered under AVIC-TECH’s official warranty.
Brigoind handles your project communications from initial inquiry through on-site commissioning guidance with multi-language support.
We coordinate after-sales support aligned with your local time zone.
For urgent inquiries, reach us via WhatsApp: +86 135 9996 3955.
Related Products



