Case Studies — Petrochemical
Petrochemical plants run continuous processes, so an unplanned trip costs far more than the equipment that caused it. The case studies in this sector cover medium-voltage soft starters and drives applied to plunger pumps, reciprocating and centrifugal compressors, and induced-draft fans on 6–10 kV networks. These loads draw six to eight times full-load current on direct-on-line starting, stressing motor windings and the upstream transformer at the same time. Every entry records the starting duty, the current-limit and ramp settings commissioned on site, and the conditions that drove the selection. Brigoind supplies Xichi and AVIC-Tech equipment as an independent distributor, not as the original manufacturer, and states that on every quotation.
500+ Clients / 30+ Countries / 24h RFQ Response
- High inrush current & mechanical stress on large gas compressor starts
- Xichi CMV-630-10 10kV soft starter for natural gas compressor
Current limit setting
300% Ie
Start ramp time
15 s
- High inrush current & mechanical stress on large plunger pump starts
- Xichi CMV series medium voltage soft starter
current limit
300% Ie
start ramp
15 s
- High inrush current & mechanical stress on large induced draft fan starts
- Five Xichi CMV-1000-10 10kV MV soft starters
Current limit setting
380% Ie
Start ramp time
45 s