| System Parameters | |
| Rated Output Power | 120 – 800 kVA (modular, N+1 redundant) |
| Module Ratings | 20 kVA / 20 kW, 30 kVA / 30 kW, 50 kVA / 50 kW |
| Max Modules per Cabinet | Up to 16 |
| Input Voltage | 3P5W, 380 / 400 / 415 VAC |
| Output Voltage | 3P4W, 380 / 400 / 415 VAC |
| Power Factor | 1.0 (kW = kVA) |
| Overload Capacity | 110% for 60 min; 125% for 10 min; 150% for 60 s |
| DC System | |
| Battery Voltage | ±180 ~ ±300 VDC (adjustable, 30–50 cells) |
| Battery Type | Lead-acid or LiFePO4 lithium-ion |
| Communication | |
| Communication Interface | RS485 / Modbus; optional SNMP, LBS, parallel operation |
| Physical & Protection | |
| Overall Efficiency | Up to 96.5% |
| Topology | Online double-conversion, modular N+1 |
| Dimensions (W×D×H) | 600×850×1350 mm up to 2400×850×2000 mm |
| Weight | 75 – 780 kg (varies by configuration) |

ARP Series Modular UPS — 120–800 kVA N+1 Redundant for Data Centers
Lead Time: 7 – 15 days | Shipping: Worldwide (sea / air / express) | Warranty: 2.5 years full machine
Excerpt
The ARP Series Modular UPS is a scalable, fully redundant online double-conversion power system covering 120 to 800 kVA, purpose-built for data centers, government facilities, financial data centers, telecommunications hubs and enterprise IT rooms. Unlike traditional tower UPS where a single failure takes down the entire system, the ARP distributes power, bypass and control functions across hot-swappable modules — if any module fails, the remaining units carry the load instantly.Each power module is 20 kVA, 30 kVA or 50 kVA, and up to 16 modules can be installed in a single cabinet. This N+1 redundancy eliminates single points of failure, while the modular design allows capacity to grow from 120 kVA up to 800 kVA without replacing the entire UPS system. Efficiency reaches 96.5% at full load, significantly reducing ongoing electricity cost for 24/7 data center operation.The ARP supports both lithium-ion and lead-acid battery banks with adjustable DC bus voltage (±180 to ±300 VDC), allowing flexible battery configuration. RS485/Modbus communication with optional SNMP and parallel operation support integrates with DCIM platforms and multi-unit redundancy systems. For voltage sag protection beyond UPS ride-through, pair with the AVR Series Dynamic Voltage Restorer.
Key Features
N+1 Full Module Redundancy
Power, bypass and control are all modular — if any module fails, the remaining units carry the load without interruption, eliminating single points of failure that cause unplanned data center downtime.
Hot-Swappable 20/30/50 kVA Modules
Add or replace power modules while the UPS is running, no shutdown required. Start at 120 kVA and scale up to 800 kVA by adding modules as your IT load grows.
Up to 96.5% Efficiency
Delivers industry-leading efficiency that cuts electricity cost for 24/7 data center operation — compared to 92% traditional UPS, the savings over 5 years are substantial.
Power Factor 1 Output
Delivers real kW matching kVA rating, so you get full usable capacity from every module — no hidden de-rating for power factor.
Flexible Battery: Lithium or Lead-Acid
Adjustable ±180 to ±300 VDC bus supports both VRLA and LiFePO4 battery banks, allowing you to choose the battery technology that fits your lifecycle cost and space requirements.
Overload: 150% for 60 Seconds
Handles 150% overload for 60 seconds and 125% for 10 minutes, providing sufficient ride-through capacity for transient load conditions without triggering bypass.
Technical Specifications
Typical Applications
The ARP Series is engineered for environments where a single power event can stop production or lose revenue. Wherever continuity matters — in data centres, plants, grids and critical sites — it delivers clean, reliable power when you need it most.
Data Centre & Server Room
Keeps racks, cooling and network infrastructure online through mains failure, brownouts and switching, with zero transfer time and clean sinewave output.
Telecommunications
Protects switching, transmission and BTS/edge sites where a dropped call or a down base station means lost revenue.
Industrial Plants
Guards PLCs, drives, robots and process lines against grid dips and outages, cutting downtime, scrap and rework.
Power Plant & Substation
Backs up protection, control, SCADA and metering systems in generation, transmission and distribution, even in harsh electrical environments.
Healthcare
Provides clean, uninterrupted power for medical imaging, diagnostics and life-support equipment.
Railway & Transportation
Supplies reliable power for signalling, control rooms and station services across fluctuating grid conditions.
Semiconductor & High-Tech
Guards precision tools and clean-room utilities where a single glitch can scrap an entire batch.
Commercial & Office Buildings
Delivers quiet, reliable backup for lifts, security, HVAC and business-critical office loads.
Frequently Asked Questions
What is the difference between modular UPS and traditional tower UPS?
A modular UPS distributes power, bypass and control across hot-swappable modules in a single cabinet. If one module fails, the others carry the load. A traditional tower UPS is a single unit — if it fails, the entire load is lost.
What does N+1 redundancy mean?
N+1 means you have enough power modules to handle the full load (N) plus one extra module for redundancy. If any single module fails, the extra module covers the load without interruption. For example, a 300 kVA system with 6×50 kVA modules can lose one module and still deliver 250 kVA of capacity.
Can I start small and expand later?
Yes. The ARP starts at 120 kVA and scales up to 800 kVA by adding 20/30/50 kVA power modules as your data center load grows. This means you can invest based on current needs and expand without replacing the entire UPS.
What battery options are available?
The ARP supports both traditional TB/TBJ VRLA lead-acid batteries and LiFePO4 lithium-ion batteries. The adjustable ±180 to ±300 VDC bus allows flexible battery sizing.
Is this suitable for cloud and internet data centers?
Yes. The ARP is specifically designed for internet data centers, colocation facilities, government data centers and financial server rooms — where uptime is critical and modular scalability is essential.
Who should I contact for this UPS — the factory or Brigoind?
Please contact Brigoind. We are the authorized distributor & engineering partner for AVIC-TECH power systems outside China.
What you receive is far more than a UPS unit — it is a full project delivery package, including load calculation, system sizing, single-line diagram design, battery runtime calculation, tender document preparation, lead-time confirmation, export packaging, ocean freight arrangement and customs documentation.
The UPS equipment is manufactured at AVIC-TECH’s factory in China. Every unit comes with factory test reports and relevant product certification documents, and is covered under AVIC-TECH’s official warranty.
Brigoind handles your project communications from initial inquiry through on-site commissioning guidance with multi-language support.
We coordinate after-sales support aligned with your local time zone.
For urgent inquiries, reach us via WhatsApp: +86 135 9996 3955.